Fault:
Alarm 700101: Set-up station not moved to 0 degree or not fixed.
Remedy:
Checked I/O status on control console and found E45.7 being ‘0’. After further check S45.7 was found malfunctioning. Replaced it and the machine returned to normal.
Alarm 700101: Set-up station not moved to 0 degree or not fixed.
Checked I/O status on control console and found E45.7 being ‘0’. After further check S45.7 was found malfunctioning. Replaced it and the machine returned to normal.
When the serial communication with DMC80H is not smooth, the possible reasons are improper parameter setting, wrong or poor hardware connection, improper use of software, or errors in transferred program, etc. Sometimes it’s really a lot of trouble to find the problem. To our experience, communication parameters can be simply set as follows:
Baud rate 19200
No parity
Stop 2
Data 7